Case study · Petworth (GU28)
Underground motor repair
Repairing a broken underground motor. Due to a lack of drainage the motor, the motor got water ingress and broke the bearings inside.

Job specification
Location
Petworth GU28
Manufacturer
Came
Voltage
24volts
Automation
Underground automation
Motor
FrogA24E
Brief
Replaced two broken gate motors with two new motors. Broke the concrete down the side of the foundation cases. We dug a 750mm deep hole and placed a 75mm soakaway drainage pipe from the motor case to our drainage hole. we then placed shingle back around the pipes in the holes and concreted back around the motor casing of both motors
Video
See it working
More case studies